Login for Software/Firmware Downloads

To prevent automated spam submissions leave this field empty.
       

VBT-75P

Vacuum Bottle Tester

 
       
9116-UC [VBT-75P]
This product is no longer in production.
  • Automatic testing
  • 10 kV - 75 kV DC output in 5 kV steps
  • Selectable test time duration from 5 seconds to 2 minutes
  • Built-in 2-1/2" thermal printer
  • Stores 84 records internally (of 16 readings each)
  • Digital voltage and current display
  • Failure indicator LED
  • Very lightweight (12 lbs./5.44 Kg)
       

VBT-75P

Technical Specifications

 
       
PHYSICAL SPECIFICATIONS Dimensions: 17”W x 10.5”H x 6.5” D (42.7 cm x 26.9 cm x 16.5 cm)
Weight: 12 lbs. (5.44 Kg)
INPUT POWER 90 - 240 Vac, 2A, 50/60 Hz
OUTPUT VOLTAGE 10kV - 75 kV dc in 5 kV steps; accuracy: 1.5%
OUTPUT  RIPPLE VOLTAGE 3% max
DISCHARGE TIME maximum discharge time for internal high voltage is 3 seconds
DISPLAY back-lit LCD (20 characters x 4 lines); viewable in bright sunlight and low-light levels
FAILURE INDICATOR failure indicator LED illuminates when test current exceeds 100 µA, 200 µA, 300 µA (programmable)
KEYPAD rugged membrane keypad (10 alpha-numeric keys, 6 function keys)
INTERNAL DATA STORAGE stores up to 84 records of 16 readings each
PRINTER built-in 2-1/2” wide thermal printer
PC SOFTWARE Windows®-based software is included with purchase price
COMPUTER INTERFACE one RS-232C port
TEMPERATURE Operating: -10°C to +50°C (+15°F to +122°F)
Storage: -30°C to +70°C (-22°F to +158°F)
HUMIDITY 90% RH @ 40°C (104°F) non-condensing
ALTITUDE 2,000 m (6,562 ft) to full safety specifications
CABLES one 10-foot high-voltage cable, one 10-foot high voltage return cable, one ground cable, one power cord
FURNISHED ACCESSORIES shipping case is included
WARRANTY one year on parts and labor
Specifications are valid at nominal voltage and ambient temperature of +25˚C (+77˚F).
Last updated on March 18, 2015