TYPE |
Portable micro-ohmmeter |
PHYSICAL SPECIFICATIONS |
16.8” W x 12.6” H x 10.6” D (42.7 cm x 32.0 cm x 26.9 cm); Weight: less than 42 lbs (19 kg) |
INPUT POWER |
100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz |
RESISTANCE READING RANGE |
1 micro-ohm – 300 milli-ohms (1 micro-ohm resolution); Accuracy: ±1% reading, ± 1 count |
TEST CURRENT RANGE |
10 Amperes – 200 Amperes, selectable |
DISPLAY |
1-inch high back-lit LCD Screen (16 characters by 2 lines); viewable in bright sunlight and low-light levels |
INTERNAL TEST RECORD STORAGE |
Stores and can display last 3 readings |
COMPUTER INTERFACE |
RS-232C port (19,200 Baud) for factory calibration and diagnostics |
SAFETY |
Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards |
ENVIRONMENT |
Operating: -10˚ to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-22˚F to +158˚ F) |
CABLES |
30-foot (#1 AWG) test cables, ground cable, power cord |
OPTIONS |
Transportation case, 15-foot test cables, C-clamps, Handspike |
WARRANTY |
One year on parts and labor |
Specifications are valid at nominal voltage and ambient temperature of +25˚C (+77˚F). Last updated on February 13, 2009 |